SS Series Fig 9095SS Overfill Prevention Valve

Brand: Morrison Bros. Co.
The 9095SS valve is installed at the fill port of a storage tank. Designed for use in pressurized fill systems and requires a tight fill connection.

The valve installs on a 2” NPT male riser connection on low profile tanks requiring a high level shut-off. The valve terminates the fill when the product reaches the preset level.

Compatible for use with diesel exhaust fluid (DEF).

Maximum Pressure- 100 PSI

Maximum Viscosity- 300 Centistokes

For use on clean liquids only.
Features
  • Designed for fill applications that do not require a drop tube
  • Can be field adjusted to the desired 90% or 95% shut off level by adjusting the shut-off tube
  • The valve design allows for full product flow until it reached the shut-off level
  • Typical flow rate is 164 GPM at 10 PSI pressure drop
  • 5 PSI is the minimum flow requirement for the valve to operate. The valve will not work in gravity filling applications
  • Can be retrofitted to existing tanks
  • Integral pressure relief
  • The vertical style float allows for installation in openings in close proximity to the tank wall
  • Immediate and cushioned shutoff…full flow up to within 1-2 seconds of closing and no abrupt kickback or line shock when valve closes
  • Dry disconnect…after shut off product is allowed to automatically drain from the highest point so fill nozzle can be removed without spilling
  • Simple mechanics…minimum moving parts. Shutoff is activated by basic hydraulic principle with no springs, levers or complicated sequence leading to closure
show more
The 9095SS valve is installed at the fill port of a storage tank. Designed for use in pressurized fill systems and requires a tight fill connection.

The valve installs on a 2” NPT male riser connection on low profile tanks requiring a high level shut-off. The valve terminates the fill when the product reaches the preset level.

Compatible for use with diesel exhaust fluid (DEF).

Maximum Pressure- 100 PSI

Maximum Viscosity- 300 Centistokes

For use on clean liquids only.
Features
  • Designed for fill applications that do not require a drop tube
  • Can be field adjusted to the desired 90% or 95% shut off level by adjusting the shut-off tube
  • The valve design allows for full product flow until it reached the shut-off level
  • Typical flow rate is 164 GPM at 10 PSI pressure drop
  • 5 PSI is the minimum flow requirement for the valve to operate. The valve will not work in gravity filling applications
  • Can be retrofitted to existing tanks
  • Integral pressure relief
  • The vertical style float allows for installation in openings in close proximity to the tank wall
  • Immediate and cushioned shutoff…full flow up to within 1-2 seconds of closing and no abrupt kickback or line shock when valve closes
  • Dry disconnect…after shut off product is allowed to automatically drain from the highest point so fill nozzle can be removed without spilling
  • Simple mechanics…minimum moving parts. Shutoff is activated by basic hydraulic principle with no springs, levers or complicated sequence leading to closure

Specifications

Body Material

  • Stainless Steel

Material of Construction

  • Float: Polypropylene
  • Adapter: Stainless Steel
  • Plunger & Dashpot: Stainless Steel
  • Float Tube & Float Guard; Stainless Steel
  • Shut-off Mechanism: Stainless Steel

Wetted Material

  • Stainless Steel Alloys 304 and 316, Teflon and Polypropylene

Viscosity

  • Max 300 centistokes

Flow Rate

  • 164 GPM @ 10 psi

Maximum Pressure

  • 100 psi

Opening Pressure

  • Min. 5 psi

Size

  • 2"

Applications

  • Storage Tank