Images are representations only.

710F Solenoid Valve - Brass (FKM), Flanged

Brand: Morrison Bros. Co.
Normally closed solenoid valves are used to help prevent the accidental siphoning of a product from a tank in the event of a leak downstream below the liquid level.

Generally installed on the dispensing side of a fuel system pipeline.

The valve opens upon the receipt of an electronic signal such as when a dispenser or pump is switched to the on position.

NOTE: Product can only be pumped in one direction, the direction of the flow arrow. Not designed for use as an overfill prevention or process control valve.
Features
  • Normally closed, hung piston design
  • Install in a horizontal pipeline in the upright vertical position
  • Minimum operating temperature is -40° F
  • Zero pressure differential
  • Integral thermal relief allows the valve to relieve expansion pressure in the opposite direction of flow
  • Continuous duty Class H standard coil operates at 120 volts
  • Enclosure is watertight and rated for hazardous locations -NEMA 3, 4X, 7 and 9; groups C and D
  • Several optional coil voltages available
  • Flanged body connections
  • Recommended for use with liquids having a maximum viscosity of 60 centistokes
  • A strainer with a 100 mesh screen is recommended at the valve inlet
show more
Normally closed solenoid valves are used to help prevent the accidental siphoning of a product from a tank in the event of a leak downstream below the liquid level.

Generally installed on the dispensing side of a fuel system pipeline.

The valve opens upon the receipt of an electronic signal such as when a dispenser or pump is switched to the on position.

NOTE: Product can only be pumped in one direction, the direction of the flow arrow. Not designed for use as an overfill prevention or process control valve.
Features
  • Normally closed, hung piston design
  • Install in a horizontal pipeline in the upright vertical position
  • Minimum operating temperature is -40° F
  • Zero pressure differential
  • Integral thermal relief allows the valve to relieve expansion pressure in the opposite direction of flow
  • Continuous duty Class H standard coil operates at 120 volts
  • Enclosure is watertight and rated for hazardous locations -NEMA 3, 4X, 7 and 9; groups C and D
  • Several optional coil voltages available
  • Flanged body connections
  • Recommended for use with liquids having a maximum viscosity of 60 centistokes
  • A strainer with a 100 mesh screen is recommended at the valve inlet

Specifications

Certifications & Approvals

  • CSA
  • cULus

Body Material

  • Cast Bronze

Seal Material

  • FKM

Environmental Protection

  • NEMA 3, 4X, 7 and 9

Voltage

  • 120 Vac (24, 208, 220, 240, & 480 Vac, and 12, 24, and 48 Vdc available)

Operating Temperature

  • Minimum -40° F

Thread Size

  • 3/4" NPT to 3" NPT

Orifice Size

  • 3/4" to 3"

Applications

  • Storage Tank