Images are representations only.

Smith Meter® Model JA10 Meter

Brand: TechnipFMC
The Smith Meter® Model JA10 Meter is a 10", double-case, straight-through-type, rotary vane, positive displacement flow meter and is part of the crude transportation (CT) series of large PD meters.

The crude transportation series PD Meters incorporate design features including lightened blades, full-width wear strips, and tungsten carbide roller pins to provide extended service in harsh crude applications.

The crude transportation series is suitable for both crude oil and refined product applications such as blending, batching and leak detection as well as traditional custody transfer applications.
Features
  • High-viscosity meter clearances extend operation at maximum flow rate from 200 to 2,000 millipascal-second (mPa•s)
  • High-temperature clearances extend operating temperatures from 125 to 200 degrees Fahrenheit (°F) (52 to 93 degrees Celsius (°C))
  • All iron trim option for operating temperatures above 200°F (93°C)
  • Liquefied petroleum gas (LPG) trim option for low-lubricity liquids, such as LPG
  • Compliant with NACE standard MR-01-75
  • ASME Section VIII vessel construction is available for model JA10-S3
show more
The Smith Meter® Model JA10 Meter is a 10", double-case, straight-through-type, rotary vane, positive displacement flow meter and is part of the crude transportation (CT) series of large PD meters.

The crude transportation series PD Meters incorporate design features including lightened blades, full-width wear strips, and tungsten carbide roller pins to provide extended service in harsh crude applications.

The crude transportation series is suitable for both crude oil and refined product applications such as blending, batching and leak detection as well as traditional custody transfer applications.
Features
  • High-viscosity meter clearances extend operation at maximum flow rate from 200 to 2,000 millipascal-second (mPa•s)
  • High-temperature clearances extend operating temperatures from 125 to 200 degrees Fahrenheit (°F) (52 to 93 degrees Celsius (°C))
  • All iron trim option for operating temperatures above 200°F (93°C)
  • Liquefied petroleum gas (LPG) trim option for low-lubricity liquids, such as LPG
  • Compliant with NACE standard MR-01-75
  • ASME Section VIII vessel construction is available for model JA10-S3

Specifications

Brand

Maximum Flow Rate

  • Continuous Rating with Standard Trim: 3500 BPH / 550 m³/h
  • Continuous Rating with All Iron or LPG Trim: 2600 BPH / 420 m³/h

Repeatability

  • ± 0.02 %

Viscosity

  • Standard: 200 mPa.s³ (1,000 SSU) maximum
  • Optional: 2 Pa.s (10,000 SSU) maximum – specify “High Viscosity Meter Clearances.”
  • Over 2 Pa.s: Specify “High Viscosity Meter Clearances” and derate maximum flow rate in direct proportion to viscosity over 2 Pa.s (e.g., at 4 Pa.s, derate maximum flow rate to 50% of normal continuous rating - 1750 BPH)

Temperature - Standard Meter Clearances with

  • Buna-N/PTFE: -20°F to 125°F (-29°C to 52°C)
  • FKM: 10°F to 125°F (-12°C to 52°C)
  • Low Temperature FKM: -50°F to 125°F (-46°C to 52°C)

Temperature - High Temperature Meter Clearances with

  • Buna-N/PTFE: -20°F to 200°F (-29°C to 93°C)
  • FKM: 10°F to 200°F (-12°C to 93°C)
  • Low Temperature FKM: -50°F to 200°F (-46°C to 93°C)

Temperature - All Iron Trim with

  • Buna-N: -20°F to 225°F (-29°C to 108°C)
  • PTFE: -20°F to 400°F (-29°C to 205°C)
  • FKM: 10°F to 400°F (-12°C to 205°C)